Water heaters for heat pump systems SUNSYSTEM SWP N – with one coil

от 625,00 лв.

With extra-sized heat exchanger surface; suitable for solar water heating, space-heating, and heat pump systems with large number of consumers.

Features

Energy Efficiency

Aesthetic PVC jacket

Easy installation

Convenient inspection opening

Optional kit for electric heating

Product features:

  • High efficiency insulation and outer casing of PVC with RAL 9006 color.
  • Multi-position mounting of temperature sensor.
  • Complex corrosion protection realized by means of titanium enamel and anode protection.
  • All threads are internal.
  • Easy installation.
  • Convenient inspection opening.
  • High efficiency heat exchanger coil
  • Optional kit for electric heating with nominal power 3kW, 4.5kW, 6kW or 7.5kW.

Elements:

1 – Aesthetic PVC jacket with color RAL 9006
2 – Highly efficient thermal insulation
3 – Anode protector (DIN 4753-6)
4 – Thermometer
5 – Water tank of low-carbon steel
6 – Titanium enamel (DIN 4753-3)
7 – Electric heating element
8 – Inspection opening with flange cover
9 – Thermostat with integrated thermal protection
10 – Safety valve, 8 bar
11 – High efficiency heat exchanger coil

Modifications and sizes, Liters:

  • 150, 200, 300, 400, 500

Energy Efficiency

  • Directive 2010/30 /EU, Regulation 812/2013:
  • Class С – depending on the volume of the water heater

Technical specifications

 

SWP N SWP N 150 SWP N 200 SWP N 300 SWP N 400 SWP N 500
capacity L 150 200 300 400 500
Height H / Installation height mm 1070/1210 1340/1460 1420/1580 1470/1670 1720/1890
diameter D mm ø 560 ø 560 ø 660 ø 750 ø 750
Rab.nalyagane / max. temperature bar/°C 10/95 10/95 10/95 10/95 10/95
Test pressure tank bar 15 15 15 15 15
Down coil S1
surface m2 1.4 1.9 2.3 2.8 3.3
Capacity coil L 8.6 11.7 14.8 17.2 20
Continuous power
DIN 4708; 80/60/45 ° C
kW
m3 /h
40.4
0.99
51
1.25
62
1.52
75
1.84
84
2.06
NL – a power coefficient. at 60 ° C 6 8 20 27 34
Pressure loss Δp mbar 120 150 400 600 710
Working pressure /
max. temperature of the coils
bar/°C 16/110 16/110 16/110 16/110 16/110
Pressure test coil bar 25 25 25 25 25
thermometer опция опция опция опция опция
anode да да да да да
El. Heater (optional) kW 3/4.5/6 3/4.5/6 3/4.5/6 3/4.5/6/7.5 3/4.5/6/7.5
weight kg 70 90 121 165 190
Lower output coil S1 A, mm G1″/182 G1″/182 G1″/215 G1″/270 G1″/270
Login cold water B, mm G1″/182 G1″/182 G1″/215 G1¼“/270 G1½“/270
Login lower coil S1 C, mm G1″/872 G1″/1122 G1″/1155 G1″/1210 G1″/1350
Exit upper coil S2 E, mm
thermoregulator G, mm G½“/697 G½“/967 G½“/1054 G½“/1054 G½“/1206
recirculation R, mm G¾“/652 G¾“/922 G¾“/1007 G1″/1105 G1″/1206
Login upper coil S2 I, mm
Exit hot water K, mm G1″/895 G1″/1160 G1″/1182 G1¼“/1240 G1½“/1453
venting F, mm G1″/1070 G1″/1340 G1″/1410 G1″/1460 G1″/1710
Manhole / flange O, ø
mm
110/180
309
110/180
309
110/180
320
110/180
450
110/180
450
draining Y, mm G1″/30 G1″/30 G1″/30 G1″/30 G1″/30
anode P, mm G1¼“/1070 G1¼“/1340 G1¼“/1410 G1¼“/1318 G1¼“/1568
Electric heater (optional) U, mm G1½“/309 G1½“/309 G1½“/320 G1½“/450 G1½“/450
Slot for additional sensor Z, mm G½“/410
G½“/868
G½“/410
G½“/11380
G½“/430
G½“/1170
G½“/560
G½“/1152
G½“/560
G½“/1453
Do NOT follow this link or you will be banned from the site!