Hygienic combi tank SUNSYSTEM HYG BR2 EF – with two coils
Coil-in-Tank construction- Flexible stainless-steel coil for sanitary hot water +Buffer tank powering space-heating system.
Sanitary water heats up instantaneously as it flows through the large surface stainless coil. Thus water is delivered hot while still fresh and clean of depositions.
Allows utilization of up to three external heat sources and an optional electric heating element.
HYG BR2 EF | HYG BR2 EF | HYG BR2 | HYG BR2 EF | ||
---|---|---|---|---|---|
500 | 800 | 1000 | 1500 | ||
Capacity | L | 500 | 800 | 1000 | 1500 |
Buffer tank /Capacity of water tank DHW | L | 480/20 | 775/25 | 975/25 | 1464 /36 |
Height without insulation / with insulation | mm | 1700/1750 | 1840/1910 | 2040/2110 | 2170/2240 |
Min. vertical clearance | mm | 1720 | 1865 | 2074 | 2262 |
Diameter without insulation / with insulation | mm | ø 650/850 | ø 790/1030 | ø 790/1030 | ø 1000/1240 |
Heat exchange surface | m2 | 5,06 | 6,11 | 6,11 | 8,93 |
Lower coil S1 | |||||
Heat exchange surfacе | m2 | 1,6 | 2,3 | 2,48 | 3,4 |
Capacity | L | 9,8 | 14 | 15,2 | 20,65 |
Upper coil S2 | |||||
Heat exchange surfacе | m2 | 1,1 | 1,71 | 1,71 | 1,93 |
Capacity | L | 6,6 | 10,5 | 10,5 | 11,85 |
Operating pressure/Max. coil temperature | bar/°C | 16/110 | 16/110 | 16/110 | 16/110 |
Operating pressure / Max. buffer temperature | bar/°C | 3/95 | 3/95 | 3/95 | 3/95 |
Operating pressure / Max. DHW tube temperature. | bar/°C | 6/95 | 6/95 | 6/95 | 6/95 |
Continuous outflow 10/45°C buffer tank is charged to 65°C. | L/h | 1080 | 1840 | 1840 | 2800 |
Continuous outflow 10/38°C, | L/h | 1350 | 2300 | 2300 | 3500 |
buffer tank is charged to 65°C. | |||||
Recommended boiler size, connected to buffer tank | kW | 44 | 75 | 75 | 114 |
Single discharge capacity up to 38°C | L | 375 | 580 | 790 | 1150 |
(when the buffer is charged to 65°C) | |||||
ΔT -temperature difference between buffer tank and | 6/8/12 | 3,5/5/8 | 3,5/5/8 | 2/3/5 | |
DHW at flow rate 30/40/50 liters/minute | |||||
Water stratification unit | mm | ø140 | ø140 | ø140 | ø140 |
Thermometer | option | ||||
Electric Heater | option | ||||
Weight without insulation / insulation | Kg | 160/12.3 | 200/16.4 | 230/18 | 360/23.2 |
outlet heat carrier boiler | A, mm | G1½”/150 | G1½”/170 | G1½”/170 | G1½”/235 |
outlet heat carrier boiler | B, mm | G1½”/150 | G1½”/170 | G1½”/170 | G1½”/235 |
outlet heat carrier boiler | C, mm | G1½”/150 | G1½”/170 | G1½”/170 | G1½”/235 |
outlet heat carrier/lower coil S1 | D, mm | G1″/325 | G1″/350 | G1″/390 | G1″/445 |
Heat carrier boiler | E, mm | G1½”/430 | G1½”/470 | G1½”/500 | G1½”/690 |
Sensor sleeve | F, mm | G½”/540 | G½”/590 | G½”/620 | G½”/800 |
Sensor sleeve | G, mm | G½”/650 | G½”/710 | G½”/770 | G½”/920 |
Inlet heat carrier/lower coil S1 | H, mm | G1″/775 | G1″/845 | G1″/930 | G1″/1045 |
Heat carrier boiler/ Electric Heater | I, mm | G1½”/900 | G1½”/930 | G1½”/1050 | G1½”/1280 |
outlet heat carrier/ upper coil S2 | J, mm | G1″/1030 | G1″/1050 | G1″/1210 | G1″/1405 |
Sensor sleeve | K, mm | G½”/1140 | G½”/1160 | G½”/1320 | G½”/1520 |
Sensor sleeve | L, mm | G½”/1420 | G½”/1520 | G½”/1700 | G½”/1790 |
Inlet heat carrier/upper coil S2 | M, mm | G1½”/1360 | G1½”/1410 | G1½”/1570 | G1½”/1720 |
Inlet heat carrier | N, mm | G1½”/1450 | G1½”/1550 | G1½”/1740 | G1½”/1820 |
Inlet heat carrier | O, mm | G1½”/1450 | G1½”/1550 | G1½”/1740 | G1½”/1820 |
Air Vent | P, mm | G1½”/1700 | G1½”/1840 | G1½”/2040 | G1½”/2170 |
Heat carrier boiler | R, mm | G1½”/1030 | G1½”/1050 | G1½”/1210 | G1½”/1405 |
Heat carrier boiler | S, mm | G1½”/1030 | G1½”/1050 | G1½”/1210 | G1½”/1405 |
Outlet hot water HYG | T, mm | G1″/1480 | G1″/1590 | G1″/1760 | G1″/1850 |
Inlet cold water HYG | U, mm | G1″/250 | G1″/270 | G1″/310 | G1″/345 |
Water heater Capacity, L | Connection | Lenght L, mm | Current, W | Voltage, V |
---|---|---|---|---|
500 | 1 1/2” | 410 | 6000 | 230 |
800 | 1 1/2” | 590 | 7500 | 230/400 |
1000 | 1 1/2” | 590 | 7500 | 230/400 |
1500 | 1 1/2” | 590 | 7500 | 230/400 |