Wood gasifying boiler BURNiT PyroBurn Lambda
от 5918,00 лв.
A highly-efficient wood gasifying boiler, designed for economical and ecological heating of medium to large-sized premises.
The PB Lambda boiler provides intuitive operation interface, heat output regulation. cleaning system and Lambda oxygen sensor as well as sophisticated safety systems.
Thanks to the integrated lambda sensor the combustion process is optimized to such an extent that boiler efficiency exceeds 91%, and exhaust gas emissions conform to strictest EU standards. The water mantle embraces the combustion chamber in full to utilize the emitted heat most efficiently.
Built-in high temperature ceramic plates ensure uniform heat distribution and protection of the water mantle from the extreme heat produced by wood gasification (up to 1200°C).
Tested and approved according to EN 303-5, class 5.



| LAMBDA | PB 25 LAMBDA | PB 30 LAMBDA | |
| Rated power / Minimum ÷ Maximum power | kW | 25 / 22÷27 | 30 / 27÷30 |
| Mass flow usr. gases maximum power | kg/s | 0.017 | 0.02 |
| height H | mm | 1285 | 1435 |
| Width L / D Depth | mm | 675/1130 | 765/1130 |
| Volume water jacket | L | 75 | 85 |
| Volume combustion chamber | L | 98 | 143 |
| Required chimney draft | Pa/mbar | 10÷15 /0.10÷0.15 | 10÷15 /0.10÷0.15 |
| boiler | high heat-resistant wool | ||
| Isolation Chamber Doors | ceramic elements ceramic components + high heat-resistant wool | ||
| Power electrical part | W | 200 | 200 |
| Power supply voltage | V/Hz | 230/50 | 230/50 |
| recommended fuel | firewood, humidity 15%; wood briquettes | ||
| Time to burn partial / full load | h | 10/6 | 14/8 |
| Fuel for heating season m3 10 ÷ 20 | 15÷23 | ||
| Dimensions of Education charging | mm | 490×200 | 490×260 |
| Max. length of wood | mm | 500 | 500 |
| Recommended volume of buffer | L | 1000 | 2000 |
| Temperature exhaust gas (in operation) | °C | 130-150 | 130-150 |
| Operating temperature range | °C | 65-85 | 65-85 |
| Min. temperature of the returning coolant | °C | 60 | 60 |
| Working pressure | bar | 3 | 3 |
| weight | kg | 488 | 605 |
| Login cold water | A, mm | G1¼“/ 160 | G1¼“/ 170 |
| Exit hot water | B, mm | G1¼“/ 1180 | G1¼“/ 1325 |
| Slot sensor or safety valve | К | yes | yes |
| Input / Output safety exchanger | Е, mm | R ½“/1090 | R ½“/1235 |
chimney | F, ø / mm | ø150/1000 | ø150/1135 |
| J, mm | 338 | 382 | |
| Manhole at the top | O1, mm | 400/140 | 455/200 |
| Manhole at the bottom | O2, mm | 350/140 | 350/140 |
| draining | Y, mm | R ½“/87 | R ½“/100 |
| Airflow valves for the primary air | V1, mm | 595 | 655 |
| Secondary air valve | V2, mm | 440 | 515 |
| Motor, stepper / servo actuators / | M1, mm | 595 | 655 |
| M2, mm | 440 | 515 | |
| suction fan | W, mm | 815 | 950 |
| Lambda probe | λ | yes | yes |
| Sensor Exhaust gases | T | yes | yes |
| cleaning system | S | yes | yes |
| Hole monitoring combustion | P | yes | yes |