Single-coil water heaters SUNSYSTEM SN

от 516,00 лв.

Floor standing. For indirect heating; Suitable for solar or space-heating systems.

features

Energy Efficiency
Aesthetic PVC jacket
Easy installation
Convenient inspection opening
Optional kit for electric heating

Product features:

  • High efficiency insulation and outer casing of PVC with RAL 9006 color.
  • Multi-position mounting of temperature sensor.
  • Complex corrosion protection realized by means of titanium enamel and anode protection.
  • All threads are internal.
  • Easy installation.
  • Convenient inspection opening.
  • Available modifications with vertical and horizontal orientation.
  • The heat exchanger coil enables the tank to utilize an external sources of renewable energy, such as a solar system or a biomass boiler.
  • Optional kit for electric heating with nominal power 3kW, 4.5kW, 6kW or 7.5kW.

Modifications and sizes, Liters:

  • Vertical models:
    150, 200, 300, 400, 500, 750, 1000, 1500, 2000.
  • Horizontal models:
    200, 300, 500, 1000, 1500.

Energy Efficiency

  • Directive 2010/30 /EU, Regulation 812/2013:
  • Class С

Elements:

1 – Aesthetic PVC jacket with color RAL 9006
2 – Highly efficient thermal insulation
3 – Thermometer
4 – Anode protector (DIN 4753-6)
5 – Electric heating element
6 – Water tank of low-carbon steel
7 – Titanium enamel (DIN 4753-3)
8 – Inspection opening with flange cover
9 – Thermostat with integrated thermal protection
10 – Safety valve, 8 bar
11 – Lower coil S1

Technical specifications

Vertical models

  SN 150SN 200SN 300SN 400SN 500SN 750SN 1000SN 1500SN 2000
CapacityL150200300400500750100015002000
Height / Mounting heightH, mm1070/12101340/14601420/15801490/16701720/18902000/20302050/20802310/23702310/2370
DiameterD, mmØ 560Ø 560Ø 660Ø 750Ø 750Ø 950Ø 1050Ø 1050Ø 1350
Insulation 50 mm rigid PU100 mm soft PU, removable
Oper. pressure / max. temperaturebar/0C8/958/958/958/958/958/958/958/958/95
Test pressure of tankbar131313131313131313
Electric heating element (optional)kW2 х (3÷6)2 x (3÷6)2 x (3÷6)2 x (3÷7.5)2 x (3÷7.5)2 х (3÷7.5)4 x (3÷7.5)5 x (3÷7.5)5 x (3÷7.5)
Weightkg5973104145167242286392712
Cold water inletA, mmRp1”/202Rp1”/202Rp1”/215Rp11/4”/270Rp11/2”/270Rp11/2”/300Rp11/2”/3202 х Rp11/2”/3202 х Rp11/2”/385
Hot water outletB, mmRp1”/868Rp1”/1140Rp1”/1170Rp11/4”/1204Rp11/2”/1453Rp11/2”/1630Rp11/2”/17002 х Rp11/2”/19752 х Rp11/2”/1885
RecirculationR, mmRp3/4”/450Rp3/4”/500Rp3/4”/663Rp1”/673Rp1”/831Rp1”/1405Rp1”/1487Rp1”/1487Rp1”/1635
Oper. pressure / max. Coil temp. S1bar/0C16/11016/11016/11016/11016/11016/11016/11016/11016/110
Test pressure  S1bar252525252525252525
Coil capacity S1L4,565,557,409,2511,1012,9516,6518,5025,28
Heat exchange surface S1m20,740,91,21,51,82,12,734,1
Coil inletS1i, mm, Rp1”592692805850960970107011701265
Coil outletS1o, mm, Rp1”202202215270270300320320385
Prolonged power acc. to DIN 4708;
80°C/60°C/45°C, S1
kW (m3/h)25(0.61)29(0.71)53(1.30)62(1.52)72(1.77)80(1.97)105(2.58)131(3.22)180(4.42)
NL – power coefficient at 60°C, S1NL 60°C2,54,511131832426480
Pressure drop Δp, S1Δp, mbar6575120180210210260310420
Sensor sleeve for thermostatG, mm, Rp1/2”73889299595011681435148714871685
Air ventF, mm, Rp1”107013401410148017101950202023202311
Inspection opening/FlangeO, mm, Ø, mm180/309
Ø 110
180/309
Ø 110
180/320
Ø 110
180/450
Ø 110
180/450
Ø 110
280/450
Ø 200
280/460
Ø 200
280/460
Ø 200
560/555
Ø 400
Drain sleeveY, mm, Rp1”202020202020404030
ThermometerT, mm, Rp1/2”86811381170120414531630170019751835
Anode protectorP, mm, Rp11/4”10701340141010791340143515702 х 1570/16502 х 1625/1705
Sleeve for Electric element on water tank bodyU, mm,Rp11/2” /680Rp11/2” /850Rp11/2” /850Rp11/2” /900Rp11/2” /1130Rp11/2” /10402 х Rp11/2” /11452 х Rp11/2” /12202 х Rp11/2” /1330
Sleeve for Electric element on inspection opening flangeUo, mm,Rp11/2” /309Rp11/2” /309Rp11/2” /320Rp11/2”/ 450Rp11/2” /450Rp11/2” /4502 х Rp11/2” /4603 х Rp11/2” /4603 х Rp11/2”/ 555
Additional sensor sleeveZ, mm, Rp1/2”422392407450568535520520745
Horizontal models:
  HSN 200HSN 300HSN 500HSN 1000HSN 1500
Capacity(L)20030050010001500
Height / LengthH, L, mm695/1340790/1410890/17101190/20801190/2380
DiameterD, mmØ 560Ø 660Ø 750Ø 1050Ø 1050
Insulation 50 mm rigid PU100 mm soft PU, removable
Oper. pressure / max. temperaturebar/0C8/958/958/958/958/95
Test pressure of tankbar1313131313
Electric heating element (optional)kW2 x (3÷7.5)2 x (3÷7.5)2 x (3÷7.5)2 x (3÷7.5)3 x (3÷7.5)
Weightkg73104167286392
Cold water inletA, mmRp1”/220Rp1”/260Rp11/2”/270Rp11/2”/360Rp11/2”/360
Hot water outletB, mmRp1”/220Rp1”/260Rp11/2”/270Rp11/2”/320Rp11/2”/320
RecirculationR, mmRp1”/420Rp1”/465Rp1”/515Rp1”/665Rp1”/665
Oper. pressure / max. Coil temp.S1bar/0C16/11016/11016/11016/11016/110
Test pressure  S1bar2525252525
Coil capacity S1L5,557,4011,1016,6518,50
Heat exchange surface S1m20,91,21,82,73
Coil inletS1i, mm, Rp1”540535585790790
Coil outletS1o, mm, Rp1”290290325340340
Prolonged power acc. to DIN 4708;
80°C/60°C/45°C, S1
kW (m3/h)29(0.71)53(1.30)72(1.77)105(2.58)131(3.22)
NL – power coefficient at 60°C, S1NL 60°C4,511184264
Pressure drop Δp, S1Δp, mbar260260310260310
Sensor sleeve for thermostatG, mm, Rp1/2”220260270360360
Inspection opening/FlangeO, mm, Ø, mm180/420
Ø 110
180/465
Ø 110
180/515
Ø 110
280/665
Ø 200
280/665
Ø 200
ThermometerT, mm, Rp1/2”220260270360580
Anode protectorP, mm, Rp11/4”3203603704602 x 690/770
Sleeve for Electric element on water tank bodyU, mm, Rp11/2”Rp11/2” /240Rp11/2” /238Rp11/2” /245Rp11/2” /2802 x Rp11/2” /280
Sleeve for Electric element on inspection opening flangeUo, mm,Rp11/2”Rp11/2” /420Rp11/2” /465Rp11/2” /515Rp11/2” /665Rp11/2” /665
Additional sensor sleeveZ, mm, Rp11/2”–––360580
BURNiT by SUNSYSTEM
What are cookies?

Cookies are small text files that are stored on your computer
or a mobile device when you visit our website. The individual sections below
will give you more information about the different categories of cookies that our web
site used, and the ability to change settings in this regard. Please
keep in mind that restricting and stopping cookies can lead to
stopping functionalities, incorrect operation, and limiting the user
You experience with our website.