Dual-coil water heaters SUNSYSTEM SОN PRL
от 595,00 лв.
Solarboiler with two parallel coils with a large heat exchange surface.
Internal threaded terminals.
Possibility of electricity supply (electric heater) and with independent heat sources (solar collectors, boiler).
Floor standing.
For indirect heating.
Suitable for solar and space-heating systems
Energy Efficiency
Aesthetic PVC jacket
Easy installation
Convenient inspection opening
Optional kit for electric heating



| SON PRL 200 | SON PRL 300 | SON PRL 500 | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Capacity | L | 200 | 300 | 500 | ||||||||||||
| Height / Mounting height | H, mm | 1340/1460 | 1420/1580 | 1720/1890 | ||||||||||||
| Diameter | D, mm | Ø 560 | Ø 660 | Ø 750 | ||||||||||||
| Insulation | 50 mm rigid PU | |||||||||||||||
| Oper. pressure / max. temperature | bar/0C | 8/95 | 8/95 | 8/95 | ||||||||||||
| Test pressure of tank | bar | 13 | 13 | 13 | ||||||||||||
| Electric heating element (optional) | kW | 1x (3÷6) | 2 x (3÷6) | 2 x (3÷7.5) | ||||||||||||
| Weight | kg | 90 | 125 | 196 | ||||||||||||
| Cold water inlet | A, mm | Rp1”/202 | Rp1”/215 | Rp11/2”/270 | ||||||||||||
| Hot water outlet | B, mm | Rp1”/1138 | Rp1”/1182 | Rp11/2”/1455 | ||||||||||||
| Recirculation | R, mm | Rp3/4”/757 | Rp3/4”/856 | Rp1”/1187 | ||||||||||||
| Operating pressure / Max.Coils temp. S1/S2 | bar/0C | 16/110 | 16/110 | 16/110 | ||||||||||||
| Test pressure S1/S2 | bar | 25 | 25 | 25 | ||||||||||||
| Coil capacity S1/S2 | L | 6.14/3.5 | 8.9/5.36 | 12.6/8.0 | ||||||||||||
| Heat exchange surface S1/S2 | m2 | 0.9/0.5 | 1.35/0.8 | 1.9/1.2 | ||||||||||||
| Lower coil inlet S1 | S1i, mm, Rp1” | 982 | 1085 | 1312 | ||||||||||||
| Lower coil outlet S1 | S1o, mm, Rp1” | 207 | 214 | 272 | ||||||||||||
| Upper coil inlet S2 | S2i, mm, Rp1” | 857 | 960 | 1187 | ||||||||||||
| Upper coil outlet S2 | S2o, mm, Rp1” | 402 | 414 | 550 | ||||||||||||
| Prolonged power acc. to DIN 4708; 80°C/60°C/45°C, S1 | kW (m3/h) | 29(0.71) | 58(1.42) | 72(1.77) | ||||||||||||
| Prolonged power acc. to DIN 4708; 80°C/60°C/45°C, S2 | kW (m3/h) | 18(0.44) | 25(0.61) | 34(0.84) | ||||||||||||
| NL – power coefficient at 60°C, S1/S2 | NL 60°C | 4.5/1.3 | 10.0 / 1.8 | 28.0 / 2.8 | ||||||||||||
| Pressure drop Δp, S1/S2 | Δp, mbar | 75/55 | 150 / 65 | 210/90 | ||||||||||||
| Sensor sleeve for thermostat | G, mm, Rp1/2” | 1037 | 1103 | 1208 | ||||||||||||
| Air vent | F, mm, Rp1” | 1340 | 1420 | 1720 | ||||||||||||
| Inspection opening/Flange | O, mm, Ø, mm | 180/309 Ø 110 | 180/319 Ø 110 | 180/452 Ø 110 | ||||||||||||
| Drain sleeve | Y, mm, Rp1” | 30 | 30 | 30 | ||||||||||||
| Thermometer | T, mm, Rp1/2” | 1138 | 1170 | 1455 | ||||||||||||
| Anode protector | P, mm, Rp11/4” | 1340 | 1420 | 1572 | ||||||||||||
| Sleeve for Electric element on water tank body | U, mm, | Rp11/2” /645 | Rp11/2” /852 | Rp11/2” /1111 | ||||||||||||
| Sleeve for Electric element on inspection opening flange | Uo, mm, | Rp11/2” /309 | Rp11/2” /320 | Rp11/2” /452 | ||||||||||||
| Additional sensor sleeve | Z, mm, Rp1/2” | 302/752 | 320/852 | 450/1013 | ||||||||||||