Hygienic combi tank SUNSYSTEM HYG B EF – without coil
Coil-in-Tank construction- Flexible stainless-steel coil for sanitary hot water +Buffer tank powering space-heating system.
Sanitary water heats up instantaneously as it flows through the large surface stainless coil. Thus water is delivered hot while still fresh and clean of depositions.
Allows utilization of up to three external heat sources and an optional electric heating element.
HYG B EF 500 | HYG B EF 800 | HYG B EF 1000 | HYG B EF 1500 | ||
---|---|---|---|---|---|
Capacity | L | 500 | 800 | 1000 | 1500 |
Buffer tank /Capacity of water tank DHW | L | 480/27 | 775/25 | 975/25 | 1464/36 |
Height without insulation / with insulation | mm | 1700/1750 | 1840/1910 | 2040/2110 | 2170/2240 |
Min. vertical clearance | mm | 1720 | 1865 | 2074 | 2262 |
Diameter without insulation / with insulation | mm | ø 650/850 | ø 790/1030 | ø 790/1030 | ø 1000/1240 |
Heat exchange surface | m2 | 5,06 | 6,11 | 6,11 | 8,93 |
Operating pressure / Max. buffer temp | bar/°C | 3/95 | 3/95 | 3/95 | 3/95 |
Operating pressure / Max. DHW tube temp. | bar/°C | 6/95 | 6/95 | 6/95 | 6/95 |
Continuous outflow 10/45°C, buffer tank is charged to 65°C | L/h | 1080 | 1840 | 1840 | 2800 |
Continuous outflow 10/38°C, buffer tank is charged to 65°C. | L/h | 1350 | 2300 | 2300 | 3500 |
Recommended boiler size, connected to buffer tank | kW | 44 | 75 | 75 | 114 |
Single discharge capacity up to 38°C (when the buffer is charged to 65°C) | L | 375 | 580 | 790 | 1150 |
ΔT -temperature difference between buffer tank and DHW at flow rate 30/40/50 liters/minute. |
6/8/12 | 3,5/5/8 | 3,5/5/8 | 2/3/5 | |
Water stratification unit | mm | ø140 | ø140 | ø140 | ø140 |
Thermometer | option | ||||
Electric Heater | option | ||||
Weight without insulation / insulation | Kg | 135/12.3 | 165/16.4 | 175/18 | 290/23.2 |
Boiler heat carrier outlet | A, mm | G1½”/150 | G1½”/170 | G1½”/170 | G1½”/235 |
Boiler heat carrier outlet | B, mm | G1½”/150 | G1½”/170 | G1½”/170 | G1½”/235 |
Boiler heat carrier outlet | C, mm | G1½”/150 | G1½”/170 | G1½”/170 | G1½”/235 |
Boiler heat carrier outlet | D, mm | G1″/325 | G1″/350 | G1″/390 | G1″/445 |
Heat carrier outlet | E, mm | G1½”/430 | G1½”/470 | G1½”/500 | G1½”/690 |
Sensor sleeve | F, mm | G½”/540 | G½”/590 | G½”/620 | G½”/800 |
Sensor sleeve | G, mm | G½”/650 | G½”/710 | G½”/770 | G½”/920 |
Boiler heat carrier inlet | H, mm | G1″/775 | G1″/845 | G1″/930 | G1″/1045 |
Boiler heat carrier/ El. heater | I, mm | G1½”/900 | G1½”/930 | G1½”/1050 | G1½”/1280 |
Sensor sleeve | K, mm | G½”/1140 | G½”/1160 | G½”/1320 | G½”/1520 |
Sensor sleeve | L, mm | G½”/1420 | G½”/1520 | G½”/1700 | G½”/1790 |
Heat carrier intlet | M, mm | G1½”/1360 | G1½”/1410 | G1½”/1570 | G1½”/1720 |
Heat carrier intlet | N, mm | G1½”/1450 | G1½”/1550 | G1½”/1740 | G1½”/1820 |
Heat carrier intlet | O, mm | G1½”/1450 | G1½”/1550 | G1½”/1740 | G1½”/1820 |
Air Vent | P, mm | G1½”/1700 | G1½”/1840 | G1½”/2040 | G1½”/2170 |
Boiler heat carrier | R, mm | G1½”/1030 | G1½”/1050 | G1½”/1210 | G1½”/1405 |
Boiler heat carrier | S, mm | G1½”/1030 | G1½”/1050 | G1½”/1210 | G1½”/1405 |
Outlet hot water HYG | T, mm | G1″/1480 | G1″/1590 | G1″/1760 | G1″/1850 |
Inlet cold water HYG | U, mm | G1″/250 | G1″/270 | G1″/310 | G1″/345 |
Water heater Capacity, L | Connection | Lenght L, mm | Current, W | Voltage, V |
---|---|---|---|---|
500 | 1 1/2” | 410 | 6000 | 230 |
800 | 1 1/2” | 590 | 7500 | 230/400 |
1000 | 1 1/2” | 590 | 7500 | 230/400 |
1500 | 1 1/2” | 590 | 7500 | 230/400 |