Features

Energy Efficiency
Aesthetic PVC jacket
Easy installation
Convenient inspection opening
Optional kit for electric heating

Product Features:

  • High efficiency insulation (DIN 4753-8): rigid PU, thickness 50 mm. Outer casing of PVC.
  • Complex corrosion protection realized by means of titanium enamel (DIN 4753-3)
    and anode protection (DIN 4753-6).
  • Convenient inspection opening.
  • Easy installation.
  • Enables the tank to utilize an external sources of renewable energy.
  • Equipment with electrical kit (electric heater and thermostat with built-in thermal
    protection) with optional power.

Modifications and sizes, L:

  • Water heater- 250
  • Buffer tank – 60

Energy efficiency:

  • Directive 2010/30/EU, Regulation 812/2013.
  • Class – C

Elements:

1 – Outer casing of PVC.
2 – High efficiency insulation (DIN 4753-8): rigid PU, thickness 50 mm.
3 – Water tank of low-carbon steel S235JR.
4 – Complex corrosion protection realized by means of titanium enamel (DIN 4753-3)
and anode protection (DIN 4753-6).
5 – Sleeves for temperature sensor and electric heater.
6 – Safety valve, 8 bar.
7 – Water heater
8 – Buffer tank

Technical specifications

SWPH 250
Capacity water heater 250 / 60
High/Mounting height mm H – 1720 / HM – 1910 / D – 650
Insulation 50mm hard PU
Oper. pressure / max. temperature bar/C° 10/95
Operating pressure/Max. buffer temperature bar/C° 3/95
Test pressure of tank bar 15
Weight kg 215
Cold water inlet boiler mm A – Rp1″ 530
Buffer outlet mm B – Rp1″ 95
Hot water outlet mm C – Rp1″ 1500
Buffer outlet 2 mm E – Rp1″ 250
Recirculation mm F – Rp3/4″ 1338
Operating pressure /Max. coil temperature bar/C° 16/110
Test pressure coils bar 25
Coil capacity l 28
Coils Heat exchange surface 4,27
Inlet coil/ Outlet coil mm Is – Rp1″ 1495 / Io – Rp1″ 530
Prolonged power acc. to DIN 4708;
80°C/60°C/45°C (coil)
kW(m³/h) 72(1.77)/94(2.31)
NL-power coefficient at 60°C NL 60C° 18/29
Pressure drop Δp(coil) mbar 90/120
Inspection opening / flange mm Fl – 180 / 110
hermometer mm G – Rp1/2″ 1470
Аnode protection mm An – Rp1 1/4″ 1645
Additional sensor sleeves mm I – Rp1/2″ 996   / I2 – Rp1/2″ 625
Deaeration buffer tank mm К – Rp1/2″ 311
Sensor buffer tank mm L – Rp1/2″ 238
Еlectric heater buffer tank mm N – Rp1 1/2″ 85