Buffer tanks SUNSYSTEM SPBM-R2 with two coils

Accumulates the heat generated by boiler; recommended for each
space-heating system.

Ensures optimum operating mode of biomass boiler, permitting its functioning at nominal power output even when the heating system does not need all the heat energy produced thereby.
Produced heat is accumulated and stored inside the buffer tank and can be used even when the boiler itself has cooled down.

Buffer tank design allows heat distribution of layers through integrated dividing plate and distribution plate (water stratification unit).

Features

Energy Efficiency
Aesthetic PVC jacket
Easy installation
Heat exchanger coil /coils
Optional kit for electric heating

Product Features:

  • Optional removable insulation with thickness 100mm and outer casing of  PVC with RAL 9006 color.
    Insulation type available for all models: soft PU , fleece.
    Insulation type available for H* models: rigid PU.
  • Dividing plate (Separator). Distribution plate (water stratification unit).
  • Multi-position mounting of temperature sensor
  •  Primer coated on the outside of the tank
  • All threads are internal
  • Inlet/Outlet arrangement -90 angle degrees for easy and convenient  installation. Possible installation in the corner of boiler room
  • Heat exchanger coils.
  •  Easy installation.
  • Optional kit for electric heating with nominal power  3kW, 4.5kW, 6kW or 7.5kW

Elements:

1 – Aesthetic PVC jacket with color RAL 9006
2 – Primer coated outer surface
3 – Removable insulation
4 – Water tank of low-carbon steel
5 – Dividing plate (Separator)
6 – Distribution plate (water stratification unit)
7 – Lower heat exchanger coil S1
8 – Upper heat exchanger coil S1

Modifications and sizes, L:

  • 300, 500, 800, 1000, 1500, 2000

Energy Efficiency

  • Directive 2010/30 /EU, Regulation 812/2013:
  • Class D / E, according to the insulation type; capacity from 300 to 1000 Liters;

Technical characteristics

 

  SPBM R2
300
SPBM R 2
500
SPBM R2
800
SPBM R2
1000
SPBM R2
1500
SPBM R2
2000
CapacityL300500800100015002000
Height without insulation / with insulationH, Hi, mm1410/14601700/17501838/18882039/20892140/22902131/2181
Mounting heightmm143017271877207321922220
Diameter without insulation /with insulationD, mm, Ø550/750650/850790/990790/9901000/12001200/1400
Operating pressure/Max. buffer temperaturebar/0C3/953/953/953/953/953/95
Operating pressure /Max. coil temperaturebar/0C16/11016/11016/11016/11016/11016/110
Recommended boiler size, connected to buffer tankkW6-1010-1715-2718-3327-5036-67
Weight without insulation/with insulationkg, kg i82/92124/136171/188191/209287/310360/387
Sleeve for Electric heating elementВ, mm, Rp 11/2”8609971090126012601308
Heat carrierС1, mm, Rp11/2”240239290290339388
Heat carrierС2, mm, Rp11/2”240239290290339388
Heat carrierС3, mm, Rp11/2”550643710775833848
Heat carrierС4, mm, Rp11/2”550643710775833848
Heat carrierС5, mm, Rp11/2”8609971090126013271308
Heat carrierС6, mm, Rp11/2”8609971090126013271308
Heat carrierС7, mm, Rp11/2”117014511750175018211768
Heat carrierС8, mm, Rp11/2”117014511750175018211768
Sensor sleeveА1, mm, Rp1/2”240239290290339388
Sensor sleeveА2, mm, Rp1/2”550643710775833848
Sensor sleeveА3, mm, Rp1/2”8609971090126013271308
Sensor sleeveА4, mm, Rp1/2”117014511750175018211768
Air ventF, mm, Rp11/2”141017002039203921402131
Capacity lower/upper coil S1/S2S1/S2 L5.6/2.69.8/6.614/10.515.2/10.520.65/11.8530/12.4
Heat exchange surface S1/S2S1/S2 m20.9/0.41.6/1.12.3/1.712.48/1.713.4/1.934.9/2.0
Inlet/Outlet Lower coil  S1S1i/S1o, mm, Rp1”640/240689/239785/290830/290939/3391158/388
Inlet/Outlet Upper coil  S2S2i/S2o, mm, Rp1”1170/9701451/11211550/11901750/13901821/15061768/1503
BURNiT by SUNSYSTEM
What are cookies?

Cookies are small text files that are stored on your computer
or a mobile device when you visit our website. The individual sections below
will give you more information about the different categories of cookies that our web
site used, and the ability to change settings in this regard. Please
keep in mind that restricting and stopping cookies can lead to
stopping functionalities, incorrect operation, and limiting the user
You experience with our website.