SUNSYSTEM SPLIT R32
Split heat pump
SUNSYSTEM SPLIT R32 is a new generation heat pump for heating/cooling and hot water, specially developed with the new R32 freon with a greener future in mind. The model has a high-efficiency Panasonic inverter compressor with EVI technology (direct steam injection in the compressor).
The heat pump system consists of an external and an internal unit, with built-in: control module, energy-saving circulation pump, expansion tank, electric heater and three-way valve for DHW.
SUNSYSTEM SPLIT R32 can be installed in a wide range of homes – small and medium-sized apartments, large villas, etc. The heat pump maintains the ideal temperature in your home while also producing hot water up to 55°C. Thanks to the compact design of the indoor unit, you save space in your home.
Heating with a heat pump is much more environmentally friendly and efficient compared to a fossil fuel boiler.
Energy class: A+++
Work area: от -30°C до 43°C
Heating capacity: 10 kW / 18 kW
Technology: Full DC inverter
Operation in heating and cooling modes
Efficient operation
Effective operation down to -30°C
Modern Screw less design
Built-in Wi-Fi module
SUNSYSTEM SPLIT R32-0126-1PH | SUNSYSTEM SPLIT R32-0220-3PH | |
Nominal heating power (kW) | 10 | 18 |
Heating mode: ambient temperature +7/water (entrance-exit) 30-35°C | ||
Output heating power (kW) | 6.5 ∼ 12.6 | 10.5 ∼ 22.0 |
COP | 4.21 ∼ 4.62 | 4.23 ∼ 4.63 |
Electrical power consumed (kW) | 1.41 ∼ 2.99 | 2.27 ∼ 5.20 |
Heating mode: ambient temperature +7/water (entrance-exit) 47-55°C | ||
Output heating power (kW) | 9,51 | 17,2 |
SOR | 3,14 | 2,82 |
Electrical power consumed (kW) | 3,03 | 6,1 |
Mode BGV: ambient temperature +7/water (entrance-exit) 15-55°C | ||
Output heating power BGV (kW) | 5.5 ∼ 10.5 | 8.8 ∼ 17.5 |
SOR | 3.07 ∼ 3.86 | 3.12 ∼ 3.93 |
Electrical power consumed (kW) | 1.42 ∼ 3.42 | 2.24 ∼ 5.61 |
Mode Cooling: ambient temperature 35/water (entrance-exit) 12-7°C | ||
Delivered cooling power at +35°C / water7°C (kW) | 4.2 ∼ 8.2 | 7.2 ∼ 14.2 |
EER to +35°C (cooling water 7°C) | 2.43 ∼ 3.23 | 2.56 ∼ 3.32 |
Electrical power consumed (kW) | 1.30 ∼ 3.33 | 2.17 ∼ 5.55 |
Energy efficiency class (35°C) | A+++ | A+++ |
Energy efficiency class (55°C) | A++ | A++ |
Refrigerant | R32 | |
Power supply type | singlephase | threephase |
Weight (kg) | 100 | 155 |
Connector to water pipe | 1″ DN 25 | 1″ DN 25 |
Flow rate of the heat carrier (m³/h) | 1,65 | 3 |
Power of the integrated electric heater | 3 kW | 4 kW |
External body dimensions (S х V х D ) (mm) | 1030x475x970 | 1000x480x1380 |
Internal body dimensions (S х V х D ) (mm) | 700x500x272 | 700x500x272 |
Sound pressure level of outdoor unit dB(A) | <53 | <58 |
Liquid/gas pipe diameter (mm) | 9.52/15.88 | 9.52/15.88 |
Refrigerated (R32) (кг) | 1,6 | 2.7 |
Pipeline length (m) | 5 | 5 |
Outdoor/indoor unit unevenness (m) | 4 | 7 |
Operating range outdoor temperature (°C) | -30+43 | -30+43 |
Output water temperature for heating (°C) | 20-55 | 20-55 |
Output water temperature for cooling (°C) | 7-35 | 7-35 |
Power supply voltage | 230V/1Ph/50-60Hz | 400V/3Ph/50-60Hz |
Cooling capacity: | 60-90 m²/155-235 m³ | 130-170 m²/340-430 m³ |