Hygienic combi tank SUNSYSTEM HYG B – without coil
Coil-in-Tank construction- Flexible stainless-steel coil for sanitary hot water +Buffer tank powering space-heating system.
Sanitary water heats up instantaneously as it flows through the large surface stainless coil. Thus water is delivered hot while still fresh and clean of depositions.
Allows utilization of up to three external heat sources and an optional electric heating element.
HYG B 500 |
HYG B 800 |
HYG B 1000 |
HYG B 1500 |
|||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Capacity | L | 500 | 800 | 1000 | 1500 | |||||||
Capacity of water tank DHW / Buffer tank | L1/L2 | 22/478 | 25/775 | 25/975 | 40/1460 | |||||||
Height without insulation / with insulation | H, Hi, mm | 1710/1750 | 1850/1890 | 2040/2090 | 2170/2220 | |||||||
Mounting height | mm | 1720 | 1865 | 2074 | 2262 | |||||||
Diameter without insulation / with insulation | D, mm | Ø 650/850 | Ø 790/990 | Ø 790/990 | Ø 1000/1200 | |||||||
Heat exchange surface | E, m2 | 5,5 | 6,11 | 6,11 | 9,9 | |||||||
Operating pressure / Max. buffer temp | bar/0C | 3/95 | 3/95 | 3/95 | 3/95 | |||||||
Operating pressure / Max. DHW tube temp. | bar/0C | 6/95 | 6/95 | 6/95 | 6/95 | |||||||
Weight without insulation / with insulation | kg, kg i | 119/131 | 155/171 | 164/182 | 266/289 | |||||||
Recommended boiler size, connected to buffer tank | kW | 44 | 75 | 75 | 114 | |||||||
Continuous outflow 10/45°C, buffer tank is charged to 65°C |
Е, 10/45°C, L/h | 1080 | 1840 | 1840 | 2800 | |||||||
Continuous outflow 10/38°C, buffer tank is charged to 65°C. |
Е, 10/38°C, L/h | 1350 | 2300 | 2300 | 3500 | |||||||
Single discharge capacity up to 38°C (when the buffer is charged to 65°C) | Е,38°C, L | 375 | 580 | 790 | 1150 | |||||||
ΔT -temperature difference between buffer tank and DHW at flow rate 30/40/50 liters/minute |
Е, ΔT | 6.8.12 | 3.5/5/8 | 3.5/5/8 | 2/3/5 | |||||||
Water stratification unit | Ø, mm | Ø140 | Ø140 | Ø140 | Ø140 | |||||||
Thermometer | T | оption | ||||||||||
Electric Heater | оption | |||||||||||
Boiler heat carrier outlet | С1, mm | Rp11/2”/150 | Rp11/2”/170 | Rp11/2”/170 | Rp11/2”/235 | |||||||
Boiler heat carrier outlet | С2, mm | Rp11/2”/150 | Rp11/2”/170 | Rp11/2”/170 | Rp11/2”/235 | |||||||
Boiler heat carrier outlet | C3, mm | Rp11/2”/150 | Rp11/2”/170 | Rp11/2”/170 | Rp11/2”/235 | |||||||
Boiler heat carrier outlet | C10, mm | Rp1”/325 | Rp1”/350 | Rp1”/390 | Rp1”/445 | |||||||
Boiler heat carrier | С4, mm | Rp11/2”/430 | Rp11/2”/470 | Rp11/2”/500 | Rp11/2”/690 | |||||||
Boiler heat carrier | С5, mm | Rp11/2”/1030 | Rp11/2”/1050 | Rp11/2”/1210 | Rp11/2”/1405 | |||||||
Boiler heat carrier | С6, mm | Rp11/2”/1030 | Rp11/2”/1050 | Rp11/2”/1210 | Rp11/2”/1405 | |||||||
Heat carrier intlet | С7, mm | Rp11/2”/1450 | Rp11/2”/1550 | Rp11/2”/1740 | Rp11/2”/1820 | |||||||
Heat carrier intlet | C8, mm | Rp11/2”/1450 | Rp11/2”/1550 | Rp11/2”/1740 | Rp11/2”/1820 | |||||||
Heat carrier intlet | С9, mm | Rp1”/775 | Rp1”/845 | Rp1”/930 | Rp1”/1045 | |||||||
Heat carrier intlet | C11, mm | Rp11/2”/1360 | Rp11/2”/1410 | Rp11/2”/1570 | Rp11/2”/1720 | |||||||
Sensor sleeve | А1, mm | Rp1/2”/540 | Rp1/2”/590 | Rp1/2”/620 | Rp1/2”/800 | |||||||
Sensor sleeve | А2, mm | Rp1/2”/650 | Rp1/2”/710 | Rp1/2”/770 | Rp1/2”/920 | |||||||
Sensor sleeve | А3, mm | Rp1/2”/1140 | Rp1/2”/1160 | Rp1/2”/1320 | Rp1/2”/1520 | |||||||
Sensor sleeve | А4, mm | Rp1/2”/1420 | Rp1/2”/1520 | Rp1/2”/1700 | Rp1/2”/1790 | |||||||
Boiler heat carrier / Electric heating element | В, mm | Rp11/2”/900 | Rp11/2”/930 | Rp11/2”/1050 | Rp11/2”/1280 | |||||||
Air Vent | F, mm | Rp11/2”/1710 | Rp11/2”/1850 | Rp11/2”/2040 | Rp11/2”/2170 | |||||||
Inlet/outlet DHW coil (tube) | Еi/Eo, mm Rp1” |
250/1480 | 270/1580 | 310/1760 | 345/1850 |
Water heater Capacity, L | Connection | Lenght L, mm | Current, W | Voltage, V |
---|---|---|---|---|
500 | 1 1/2” | 410 | 6000 | 230 |
800 | 1 1/2” | 590 | 7500 | 230/400 |
1000 | 1 1/2” | 590 | 7500 | 230/400 |
1500 | 1 1/2” | 590 | 7500 | 230/400 |