Tested and approved acc. European standard EN 303-5, class 5.

Features

Heating medium and large rooms
Simple installation and handling
Exchangeable metallic ash grate
Thermostatic draught regulator

Safety valve 3 bar

HEATING KIT INCLUDES:

  • Electronic control unit controls the combustion by modulating the fan speed. Optional control of circulation pumps for central heating and domestic hot water (DHW).
  • Air feed fan optimizes the combustion and the fuel consumption rate.
  • The water mantle embraces the combustion chamber in full to utilize the emitted heat most efficiently.
  • Combustion chamber with large heat exchanging surface and low chamber resistance.
  • Large firebox door ensures easy loading even with bigger logs (length of logs up to 50 cm).
  • Ribbed chamber surface and three-pass flue gas flow for improved heat exchange.
  • Exchangeable metallic ash grate protects the pipe grid from the flame.
  • Burner flange on lower door for fitting pellet, oil or gas burners (optional).

AVAILABLE SIZES, KW:

SET INCLUDES
BURNIT WBS AC PELLET 20  WBS AC 30 / PELL 30
BURNIT WBS AC PELLET 25  WBS AC 40 / PELL 30
BURNIT WBS AC PELLET 35  WBS AC 50 / PELL 40
BURNIT WBS AC PELLET 50  WBS AC 70 / PELL 70
BURNIT WBS AC PELLET 60  WBS AC 90 / PELL 70
BURNIT WBS AC PELLET 60 +  WBS AC 90 + / PELL 70

SAFETY DEVICES

  • STB – emergency thermostat – turn off the fan and stop the combustion process.
  • Pressure relief valve 3 bar;
  • Safety heat evacuator a tap-water-filled line passes through the upmost part of the boiler body. In case of overheating it is triggered open by a thermostatic valve (not included) to evacuate the heat of the boiler.
  • Air intake flap.

ELEMENTS:

  1. Cladding
  2. High-performance insulation
  3. Three-way flue gas path
  4. Water shirt (Mantel)
  5. Fuel chamber
  6. Tray
  7. Flange for burner
  8. Chimney
  9. Check valve mounted to the fan

TECHNICAL SPECIFICATION

Model   WBS A 30
– Pell 30
WBS A 40
– Pell 30
WBS A 50
– Pell 40
WBS A 70
– Pell 70
WBS A 90
– Pell 70
Nominal power kW 22 30 35 52 60
Minimum ÷ Maximum power: kW 6÷25 9÷32 10÷40 15÷65 18÷65
Mass flow usr. gases min. ÷ max. power: kg/s 0,005÷0,013 0,011÷0,025 0,007÷0,021 0,012÷0,032 0,010÷0,031
Dimensions
WBS Active + Pell
 Height H mm 1235 1235 1235 1385 1385
width L 540 700 700 700 760
D Depth 1315 1315 1375 1495 1495
Volume water mantel l 75 96 106 134 145
Volume combustion chamber l 62 84 97 120 133
Mantle resistance, Δt=20, K Pa/mbar 9/0,09 12/0,12 14/0,14 26/0,26 20/0,20
Required chimney draft Pa/mbar 10/0,10 12/0,12 14/0,14 26/0,26 30/0,30
Insulation Boiler high-efficiency thermal wool
Doors
Power consumption: Burner
Pell
Boiler WBS W 60 60 60 110 110
Ignition mode ~ 400 ~ 400 ~ 400 ~ 400 ~ 400
Operating mode ~ 60÷70 ~ 60÷70 ~ 60÷70 ~ 70÷110 ~ 70÷110
Self cleaning mode ~ 1300 ~ 1300 ~ 1300 ~ 1300 ~ 1300
Electric power supply V/Hz 230/50 230/50 230/50 230/50 230/50
Recommended fuel Pellets ENplus-A1; ENplus-A2; EN-B
Operating temperature range °C 65 – 80 65 – 80 65 – 80 65 – 80 65 – 80
Working pressure bar 3 3 3 3 3
Weight: boiler, burner kg 309/71 384/71 414/71 496/71 538/71
Inlet cold water A, mm R1¼”/232 R1¼”/232 R1¼”/232 R1¼”/232 R1¼”/232
Outlet hot water B, mm R1¼”/1265 R1¼”/1265 R1¼”/1265 R1½”/1420 R1½”/1420
Sleeve for sensor К, mm G½”/1075 G½”/1075 G½”/1075 G½”/1225 G½”/1225
Input / Output safety exchanger Е, mm R½”/1072 R½”/1072 R½”/1072 R½”/1222 R½”/1222
Chimney F ø
mm J, mm
150 180 180 200 200
945 930 930 1065 1065
270 350 350 350 380
Inspection opening O, mm 150/70 150/70 150/70 150/70 150/70
Draining Y, mm G½”/232 G½”/232 G½”/232 G½”/232 G½”/232
Ash-and-soot tray X + + + + +