Buffer tanks SUNSYSTEM PBM-R EF – with one coil

Accumulates the heat generated by boiler; recommended for each space-heating system.
Ensures optimum operating mode of biomass boiler, permitting its functioning at nominal power output even when the heating system does not need all the heat energy produced thereby.
Produced heat is accumulated and stored inside the buffer tank and can be used even when the boiler itself has cooled down.

Features

Energy Efficiency

Aesthetic PVC jacket

Easy installation

Heat exchanger coil /coils

Optional kit for electric heating

Product Features:

  • Optional removable insulation with thickness 120mm and outer casing of  PVC with RAL 9006 color.

Insulation type available for all models: soft PU , fleece.
Insulation type available for H* models: rigid PU.

  •  Multi-position mounting of temperature sensor
  •  Primer coated on the outside of the tank
  • All threads are internal
  • Inlet/Outlet arrangement -90 angle degrees for easy and convenient  installation. Possible installation in the corner of boiler room.
  • Heat exchanger coil.
  • Easy installation.
  • Optional kit for electric heating with nominal power  3kW, 4.5kW, 6kW or 7.5kW

Elements:

1 – Aesthetic PVC jacket with color RAL 9006
2 – Primer coated outer surface
3 – Removable insulation
4 – Water tank of low-carbon steel
5 – Lower coil

Modifications and sizes, L:

  • 300, 500, 800, 1000, 1500, 2000

Energy Efficiency

  • Directive 2010/30 /EU, Regulation 812/2013:
  • Class B

Technical characteristics

 

PBM R EF 300 PBM R EF 500 PBM R EF 800 PBM R EF 1000 PBM R EF 1500 PBM R EF 2000
Capacity L 300 500 800 1000 1500 2000
Diameter without insulation /with insulation mm 550/750 650/850 790/990 790/990 1000/1200 1200/1400
Height without insulation / with insulation m 1410/1460 1700/1750 1838/1888 2039/2089 2140/2290 2131/2181
Minimal vertical clearance mm 1431 1727 1877 2073 2192 2220
Lower coil S1 Heat exchange surface Capacity m2 L 0.9 1.6 2.3 2,48 3,4 4,9
L 5,9 10,5 15 16,2 22,2 32,1
Operating pressure / Max.coil temperature bar/°C 16/110 16/110 16/110 16/110 16/110 16/110
Operating pressure/Max. buffer temperature bar/°C 3/95 3/95 3/95 3/95 3/95 3/95
Boiler power to connect to the buffer kW 6-10 10-17 15-27 18-33 27-50 36-67
Weight Buffer tank / insulation Kg 75/9.5 106 /12.3 144 /16.4 126/18 205/23.2 254/26.5
Heat carrier A,mm /G1½“ 240 239 290 290 339 388
Heat carrier B,mm /G1½” 240 239 290 290 339 388
Sensor sleeve C,mm / G½” 240 239 290 290 339 388
Outlet lower coil S1 D,mm / G1″ 240 239 290 290 339 388
Heat carrier E,mm /G1½” 550 643 710 775 833 848
Sensor sleeve F,mm / G½” 550 643 710 775 833 848
Heat carrier G.mm / G1½” 550 643 710 775 833 848
Inlet lower coil S1 H,mm / G1″ 640 689 785 830 339 1158
Heat carrier I.mm / G1½” 860 997 1090 1260 1327 1308
Heat carrier J.mm / G1½” 860 997 1090 1260 1327 1308
Sensor sleeve K,mm / G½” 860 997 1090 1260 1327 1308
Heat carrier / El. heater L.mm / G1½” 860 997 1090 1260 1327 1308
Heat carrier O,mm / G1½” 1170 1451 1750 1750 1821 1768
Heat carrier P,mm / G1½” 1170 1451 1750 1750 1821 1768
Sensor sleeve Q,mm / G½” 1170 1451 1750 1750 1821 1768
Air vent sleeve S,mm / G1½” 1410 1700 2039 2039 2140 2131