Buffer tank PBM-R2 – with two coils


Accumulates the heat generated by boiler; recommended for each space-heating system.
Ensures optimum operating mode of biomass boiler, permitting its functioning at nominal power output even when the heating system does not need all the heat energy produced thereby.
Produced heat is accumulated and stored inside the buffer tank and can be used even when the boiler itself has cooled down.

Features

Energy Efficiency
Aesthetic PVC jacket
Easy installation
Heat exchanger coil /coils
Optional kit for electric heating

Product Features:

  • Optional removable insulation with thickness 100mm and outer casing of  PVC with RAL 9006 color.

Insulation type available for all models: soft PU , fleece.
Insulation type available for H* models: rigid PU.

  •  Multi-position mounting of temperature sensor
  •  Primer coated on the outside of the tank
  • All threads are internal
  • Inlet/Outlet arrangement: 90 angle degrees for easy and convenient  installation. Possible installation in the corner of boiler room
  • Heat exchanger coils.
  • Easy installation.
  • Optional kit for electric heating with nominal power  3kW, 4.5kW, 6kW or 7.5kW.

Modifications and sizes, L:

  • 300, 500, 800, 1000, 1500, 2000, 3000, 4000, 5000

Energy Efficiency

  • Directive 2010/30 /EU, Regulation 812/2013:
  • Class D / E, according to the insulation type; capacity from 300 to 1000 Liters;

Elements:

1 – Aesthetic PVC jacket with color RAL 9006
2 – Primer coated outer surface
3 – Removable insulation
4 – Water tank of low-carbon steel
5 – Lower coil S1
6 – Upper coil S2

Technical characteristics

SPBM R2
300
SPBM R 2
500
SPBM R2
800
SPBM R2
1000
SPBM R2
1500
SPBM R2
2000
CapacityL300500800100015002000
Height without insulation / with insulationH, Hi, mm1410/14601700/17501838/18882039/20892140/22902131/2181
Minimal vertical clearancemm143017271877207321922220
Diameter without insulation /with insulationD, mmØ 550/750Ø 650/850Ø 790/990Ø 790/990Ø 1000/1200Ø 1200/1400
Operating pressure/Max. buffer temperaturebar/0C3/953/953/953/953/953/95
Operating pressure /Max. coil temperaturebar/0C16/11016/11016/11016/11016/11016/110
Recommended boiler size, connected to buffer tankkW6-1010-1715-2718-3327-5036-67
Weight without insulation/with insulationkg, kg i82/92124/136171/188191/209287/310360/387
Sleeve for Electric heating elementВ, mm, Rp 11/2”8609971090126012601308
Heat carrierС1, mm, Rp11/2”240239290290339388
Heat carrierС2, mm, Rp11/2”240239290290339388
Heat carrierС3, mm, Rp11/2”550643710775833848
Heat carrierС4, mm, Rp11/2”550643710775833848
Heat carrierС5, mm, Rp11/2”8609971090126013271308
Heat carrierС6, mm, Rp11/2”8609971090126013271308
Heat carrierС7, mm, Rp11/2”117014511750175018211768
Heat carrierС8, mm, Rp11/2”117014511750175018211768
Sensor sleeveА1, mm, Rp1/2”240239290290339388
Sensor sleeveА2, mm, Rp1/2”550643710775833848
Sensor sleeveА3, mm, Rp1/2”8609971090126013271308
Sensor sleeveА4, mm, Rp1/2”117014511750175018211768
Air vent sleeveF, mm, Rp11/2”141017002039203921402131
Capacity lower/upper coil S1/S2S1/S2 L5.6/2.69.8/6.614/10.515.2/10.520.65/11.8530/12.4
Heat exchange surface S1/S2S1/S2 m20.9/0.41.6/1.12.3/1.712.48/1.713.4/1.934.9/2.0
Inlet/Outlet Lower coi  S1S1i/S1o, mm, Rp1”640/240689/239785/290830/290939/3391158/388
Inlet/Outlet Upper coil  S2S2i/S2o, mm, Rp1”1170/9701451/11211550/11901750/13901821/15061768/1503